Skip to main content

Sputter transport

A magnetron sputter process is a two-scale problem: the erosion of the target is decided by the plasma (ions, some 10 eV to 1 keV, time scale ns to µs), the transport of the sputtered atoms to the substrate by the neutral gas flow (0.1 to 10 Pa, time scale ms to s). PICMC covers both, but not in the same run - the time steps differ by four orders of magnitude. The usual way is therefore a PIC-MC plasma simulation that produces the ion bombardment profile, followed by a DSMC simulation that uses this profile as the sputter source.

This page walks through the DSMC part and shows every step in both input forms. The pieces themselves are described in Particle sources, Particle emission and DSMC / PIC-MC iteration.

The physics is the same in both forms:

  • the background gas is a DSMC species with collisions from the species and cross-section database,
  • the target emits the film species with a Thompson energy distribution,
  • the local emission flux follows an imported profile, usually the time averaged Arplus absorption of the preceding plasma run,
  • the film species sticks on the walls (absorption probability 1), the working gas is reflected.

The three ingredients​

1. A case in WORKMODE = 0. The work mode is the same keyword as in the parameter file. WORKMODE = 0 runs DSMC, so no electric field is solved and no charged species is required. FIELD plots are skipped with a message in this mode - the relevant output are number, density, pressure, temperature, velocity for the gas, and absorption plus meshdata for the film species. meshdata writes the absorbed flux per mesh element (a GMSH view on the surface mesh), which is the direct input for a thickness profile.

WORKMODE = 0;
DT = 1e-6;
TSIM = 1e-3;

2. An absorption profile from the plasma run. Put Arplus into the ABSORPTION plot list of the PIC-MC case, time average the resulting .pos files over the RF periods of interest, and copy one file next to the case. set_profile reads a GMSH POS view and expects the coordinates in mesh units, the value in the fourth component of each record:

add_source("Ta", 20, "sccm");
set_profile("absorption_Arplus.pos");
set_emission_thompson("Ta", 8.1, 1.0, 500, 40);

The profile is only a distribution: it is binned onto the volume cells touching the border and normalized over the source points of that border. The absolute flux therefore comes from source_value, not from the numbers in the profile file. This is convenient (a profile normalized to percent works) but also the most common mistake - a profile from a low density test run then still gives the flux that source_value asks for.

Ub is the surface binding energy of the emitted species (8.1 eV for Ta, 4.7 eV for Si), Eion and mion are energy and mass of the bombarding ion, here 500 eV Ar+. From these the code computes the recoil cutoff energy of the Thompson distribution itself, so a wrong mion silently changes the energy spectrum. This is the recommended form; the older command set_emission_sputter still works and gives the same distribution, but it assumes the bombarding ions (Ar, 40 u) and a cutoff of 100 times the binding energy instead of taking the real bombardment into account.

3. Reactions for the DSMC. In the parameter file the elastic cross sections come from the species definition file SCR/species_definition.r (SPECIESFILE selects another one), in Python from the pydatabase:

sim = PICMC.Sim(Specs = pydatabase.SPECIES_LIST,
Reactions = pydatabase.REACTION_LIST)

Leave the reaction data out and the sputtered atoms fly collisionless, whatever the pressure says.

Order of the reactions on a border​

The profile and the emission profile do not belong to the border, they belong to one wall reaction of it - the one that was added last. Both input forms attach set_profile and set_emission_* to the most recently declared reaction, so the list has to be ordered:

# film species sticks, the source reaction comes last
add_absorption("Ta", 1);
add_source("Ta", 20, "sccm");
set_profile("absorption_Arplus.pos");
set_emission_thompson("Ta", 8.1, 1.0, 500, 40);

Reversing the two puts the emission parameters on the absorption reaction, where they are accepted without complaint but never used, and the target then emits a Maxwellian at wall temperature.

Boundary conditions of the bounding box​

For a deposition profile one wants a defined background pressure. Two settings are sensible:

BOUNDARY_CONDITIONSbehaviour
all "specular"closed box, the initial filling P0 is kept, static gas at rest, no pumping. Cheap and consistent with the homogeneous background a PIC-MC case assumes.
all "outlet"every particle leaving the box is deleted. Combined with gas inlets this gives a flow field, but the box sides then act as a very large pump: a few 100 sccm in a 0.1 m³ volume settle at 1e-3 Pa, not at the process pressure.

The second variant only makes sense with a pump surface of realistic conductance or with gas inlets sized for the pressure that is wanted. For the film thickness this is not a detail - at 1e-3 Pa the mean free path exceeds the target-substrate distance and the profile is purely geometric. In Python the setting is Geometry(BOUNDARY_CONDITIONS = "specular"), per side as a dict of the six boundaries.

A worked case​

AP4/DSMC_TA_C32.py in the EOSS600 project ports the old RVM matrix case (Si-5e-3-Plasma.par) to the FHR process module C32 with a Ta target. The mapping:

RVM matrix casePython case
WORKMODE = 0, DT = 1e-6, TSIM = 5.0same mode and step, TSIM = 0.1 (the Ta inventory is at steady state after ~1 ms, the old run needed ~79 h)
SPECIES = ["Ar", "Si"]{"Ar": …, "Ta": …}
NREAL_Ar = 6e12, P0_Ar = 0.6adapted to the process pressure 0.35 Pa and the cell size
add_source("Si", 20, "sccm")BorderReaction(reaction_type = "source", source_value = 20, source_unit = "sccm")
set_emission_thompson("Si", 4.7, 1, 500, 40)set_emission_Thompson(species = "Ta", Ub = 8.1, alpha = 1.0, Eion = 500, mion = 40)
set_profile("…-T1-t102.5-t250.pos") per targetone profile containing both targets, each border picks its own cells
abs=1 on all wallsBorderReaction(absorption = True, probability = 1.0)

The grid is chosen from the mean free path, not from the plasma: 4.24 mm cells at 0.35 Pa (λ ≈ 19 mm for argon) give 40 x 120 x 204 cells in 288 segments; NREAL_Ar = 3e11 puts about 20 simulation particles into each cell. Both numbers are far coarser than in a PIC-MC case.

Submit it like any Python case:

python3 $PICMCPATH/py/pysubmit.py DSMC_TA_C32.py -n 48 -c IST_EPYC

with -n below the number of segments (288 here); additional segments are distributed over the available ranks. The parameter file case starts the same way through rvmslurm, with the .par file instead of the script.

What to look at afterwards​

  • absorption and meshdata for the film species: flux and thickness profile. meshdata is a surface view, so it can be opened in GMSH on the same mesh as the case.
  • pressure of the working gas: it should stay near P0 in a closed box. A pressure that keeps dropping means the box is a pump, not a chamber wall.
  • The particle counters in <case>-out.txt: the number of sputtered atoms per second should agree with source_value (1 sccm ≈ 4.48e17 particles/s per species).
  • A histogram array on a plane between target and substrate gives the angular and energy distribution the raytracer works with.